Huadian Technology ›› 2008, Vol. 30 ›› Issue (3): 67-69.

• 节能与环保 • Previous Articles     Next Articles

Analysis on economic operation of 480t/h CFB boiler

WANG Dong-chuan, MA Li-guo   

  1. Huadian Wuda Thermoelectric Corporation Limited, Wuhai 016040, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2008-03-25 Published:2008-03-25

Abstract: the boiler structure and their main operation parameters are introduced. Some problems in starting and stopping process needed to pay attention to has been pointed out. The measures to improve the EP efficiency and prevent heating surface from abrasion as well as boiler from slagging have been presented based on the operation experience .