Huadian Technology ›› 2009, Vol. 31 ›› Issue (4): 8-10.
• 专题综述 • Previous Articles Next Articles
ZHANG Li, LI Xinmin
Received:
Revised:
Published:
Abstract: Salaqi Power Plant of Shenhua Shendong Power Corporation Limited has the first 300MW CFB (Circulating Fluidized Bed) boiler made in our country; this paper introduced the main slag discharge faults in the operation and analyzed their reasons. The failures recovery and equipments reform were explained briefly. Combination with the hidden troubles in slag discharge system of CFB boiler, a set of precontrol measures was proposed.
Key words: CFB boiler, slag discharge, air plus water slag cooler, roller slag cooler, reasons analyze, precontrol
ZHANG Li;LI Xinmin. Slag discharge faults and precontrol measures of CFB boiler[J]. Huadian Technology, 2009, 31(4): 8-10.