Huadian Technology ›› 2009, Vol. 31 ›› Issue (5): 47-49.
• 技术交流 • Previous Articles Next Articles
MI Hui
Received:
Revised:
Published:
Abstract: This paper analyzes the membrane water wall leakage of the Yunfu Power Plant Corporation Limited of Guandong Yudean Groap corporation Limited No.4 boiler, it has been discovered that the stiffening bar unreasonable structure design was the primary reason to cause the problem occurring,by implementing the proposed basic method, the problem has been successfully solved,and the operation stability of the boiler membrane water wall has get a very great improvement.
Key words: membrane water wall leakage, stiffening bar, expand, crack, structure improvement, problem-solving method
MI Hui. Cause analysis and the treatment on the boiler membrane wall leakage[J]. Huadian Technology, 2009, 31(5): 47-49.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2009/V31/I5/47
Cause analysis on the fillet weld cracking of the outlet header socket of hightemperature reheater