Huadian Technology ›› 2009, Vol. 31 ›› Issue (9): 48-50.

• 研究与开发 • Previous Articles     Next Articles

Reformation of cool panel and hot panel of superheater in circulating fluidized bed boiler

SONG Zhanbing   

  1. Henan Boao Construction Corporation Limited, Gongyi 451200, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2009-09-25

Abstract: The technical characteristics and main technical parameters of 440t/h CFB boiler No.2 in Zhongfu Electric Power Corporation were introduced. Some problems were occurred frequently in the boiler operation which includes overtemperature in cool panel and hot panel of superheater, pipe explosion and local serious wear of watercooled wall in furnace. Theses problems influenced on safety operation of unit seriously. The relevant measures were adopted, the cool panel and hot panel of superheater were reformed. After the reformation, the cool panel and hot panel of superheater operate well, and pipe explosion due to overtemperature has not occurred.

Key words: circulating fluidized bed boiler, boiler heating surface, cool panel and hot panel of superheater, over-temperature, water-cooled wall, wear, reformation