Huadian Technology ›› 2009, Vol. 31 ›› Issue (9): 67-68.

• 技术交流 • Previous Articles     Next Articles

Reformation method and effects of generator ventilation system

HUANG Xiaoxia, WANG Weijiang, JIANG Cuihua   

  1. Danjiangkou Hydropower Plant, Danjiangkou 442700, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-09-25 Published:2009-09-25

Abstract: The reformation reason of No.5 generator ventilation systems in Danjiangkou Hydropower Plant was expounded. The structures and operation principles before and after reformation were introduced. The operation effects before and after reformation were analyzed and compared. The problems occurred in reformation and solving method were summarized.

Key words: generator ventilation system, reformation method, effect of reformation