Reformation of cool terminal heat exchange elements of air heater using enameled elements

BAI Xueli,ZHAO Junbin   

  1. Shanxi Zhangshan Power Generation Corporation Limited, Changzhi 046021, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-06-25 Published:2010-06-25

Abstract: The cool terminal corrosion of air heater is occurred unavoidably in sulfur coalfired boiler; even, the heat exchange element could be badly damaged and blocked; and this could cause the overlarge pressure difference of gas duct and the induced draft fan stalling, even cause the boiler shutdown. The heat exchange elements were replaced by enameled elements. After the reformation, the problem of cool terminal corrosion was solved fundamentally. 

Key words: air heater, heat recuperating element, cool terminal corrosion, reformation using enameled element