Huadian Technology ›› 2010, Vol. 32 ›› Issue (6): 57-60.
• 技术交流 • Previous Articles Next Articles
BAI Xueli,ZHAO Junbin
Received:
Revised:
Published:
Abstract: The cool terminal corrosion of air heater is occurred unavoidably in sulfur coalfired boiler; even, the heat exchange element could be badly damaged and blocked; and this could cause the overlarge pressure difference of gas duct and the induced draft fan stalling, even cause the boiler shutdown. The heat exchange elements were replaced by enameled elements. After the reformation, the problem of cool terminal corrosion was solved fundamentally.
Key words: air heater, heat recuperating element, cool terminal corrosion, reformation using enameled element
BAI Xueli;ZHAO Junbin. Reformation of cool terminal heat exchange elements of air heater using enameled elements[J]. Huadian Technology, 2010, 32(6): 57-60.