Abstract: The fault of pressure slowly decreasing occurred in the 300MW turbine EH oil system of Huadian Weifang Power Generation Corporation Limited. The factors, which probably influence on the pressure, were confirmed and eliminated one by one, and relevant measures were proposed. After a minor overhaul, the unit was startedup again, and the EH oil pressure and the oil pump motor current became normal.
Key words: 330MW turbine, EH oil, pressure decrease, motor of oil pump
L Fuzhou;MA Baohui. Analysis of EH oil system pressure decrease in 330MW turbine and treatment[J]. Huadian Technology, 2010, 32(6): 61-62.