Huadian Technology ›› 2010, Vol. 32 ›› Issue (7): 23-25.

• 研究与开发 • Previous Articles     Next Articles

Analysis on application of steam extraction heatsupply from three sections in Guangzhou Hengyun Cogeneration Power Plant

ZHANG Linjun   

  1. Guangzhou Hengyun Byproduct Power Plant, Guangzhou 510730, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-07-25

Abstract: Two design ideas and schemes for steam turbine reformation in Guangzhou Hengyun Cogeneration Power Plant were introduced, in which the exhaust of high pressure cylinder and the extraction steam from 3 sections are used as heatsupply steam source point respectively. The exergy losses of the high pressure cylinder exhaust heatsupply and the 3 sections extraction steam heatsupply were analyzed using the exergy method. The conclusion was obtained that the scheme of extraction steam heatsupply from 3 sections has smaller exergy loss, but the scheme of high pressure cylinder exhaust heatsupply is more flexible.

Key words: steam turbine reformation, steam extraction heat-supply, high pressure cylinder exhaust, steam extraction from 3 sections, exergy method