Huadian Technology ›› 2010, Vol. 32 ›› Issue (S1): 12-13.
• 研究与开发 • Previous Articles Next Articles
WANG Jiaoling, XIAO Min, ZHAO Shuping
Received:
Revised:
Published:
Abstract: In order to save energy and reduce the house service consumption rate, the condensate pumps of 2×300MW thermal power generation units of Yunnan Huadian Kunming Power Generation Corporation Limited were reformed using variable frequency technology. The modification and perfection of the thermal process control logic and the operational picture in the variable frequency reformation for the condensate pumps were introduced, and concrete requirements for operators were put forward. After the variable frequency reformation of the condensate pumps, the thermal process control logic became perfect and easy to operation, obvious energysaving effects were obtained.
Key words: condensate pump, variable frequency, thermal process control reformation scheme, thermal process control logic, operational picture
WANG Jiaoling;XIAO Min;ZHAO Shuping. Thermal process control scheme in ‘one drive two’ variable frequency reformation of condensate pump[J]. Huadian Technology, 2010, 32(S1): 12-13.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/IS1/12
Optimization of deep frequency conversion transformation for condensate pump in 1000MW secondary reheat unit