Huadian Technology ›› 2010, Vol. 32 ›› Issue (S1): 39-42.

• 技术交流 • Previous Articles     Next Articles

Analysis of vibration of shaft system in 300MW unit and treatment

LI Biao   

  1. Yunnan Huadian Kunming Power Generation Corporation Limited, Anning 650308, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-07-26 Published:2010-07-26

Abstract: In the turbine set rolling start process, the vibration is main parameter of the shaft system operation monitoring. If the vibration occurred and has not been treated in time, then the equipment may be damaged. Proper treatment can avoid effectively the equipment damage accident. The reason of the vibration of the 300MW unit No.1 of Kunming Power Generation Corporation Limited occurred during a warm start process was analyzed, and a treatment scheme was put forward.

Key words: warm start up, friction and vibration, parameters of rolling the turbine