Huadian Technology ›› 2010, Vol. 32 ›› Issue (S1): 4-5.

• 专题综述 • Previous Articles     Next Articles

Operation adjustment of the DG1025 type boiler burning poorgrade coal

LI Biao,DAI Jingyi   

  1. Yunnan Huadian Kunming Power Generation Corporation limited, Anning 650308, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-07-26 Published:2010-07-26

Abstract: From the angle of equipments, coal property and operators, the control modes have been optimized when the poorgrade coal is burned in the boiler of Yunnan Huadian Kunming Power Generation Corporation Limited. The boiler flameout faults were reduced, the abnormal fuel oil consumption was decreased; and the purposes of security and economical efficiency for the unit operation were reached.

Key words: poor-grade coal, operation adjustment, boiler flame-out, countermesure