Huadian Technology ›› 2010, Vol. 32 ›› Issue (S1): 61-62.
• 节能与环保 • Previous Articles Next Articles
LIU Jianping
Received:
Revised:
Published:
Abstract: The data of the seriflux densitometer and the pH meter in wet FDG absorption tower are important parameters for FGD system operation supervision. The installing locations of the densitometer and the pH meter are very important for decreasing the wear of the devices and the maintenance cost and for enhancing the safety and the reliability of FGD system operation. The seriflux densitometer and the pH meter of the 300MW unit FDG absorption tower in Yunnan Huadian Kunming Power Generation Corporation Limited were reinstalled in new locations. The successful experience of the location reformation was presented in this paper.
Key words: absorption tower, densitometer, pH meter, installing location reformation
LIU Jianping. Reformation of pH meter and densitometer in FGD absorption tower[J]. Huadian Technology, 2010, 32(S1): 61-62.