Reason analysis of suddenly opening of mediumpressure regulating valve in digital electrohydraulic control system

ZENG Aiping   

  1. Hunan Changsha Power Generation Corporation Limited, Changsha 410203, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-11-25 Published:2011-11-25

Abstract: In the Hunan Changsha Power Generation Corporation Limited, after the overhaul of the unit No.1, the mediumpressure regulating valve suddenly opened during rolling the turbine and warming up two times, and the rotate speed was increasing quickly and can not be controlled. The digital electrohydraulic control system and the reason of the mediumpressure regulating valve suddenly opening were analyzed in detail. After the effective measures were adopted, the suddenly opening of the mediumpressure regulating valve was not occurred again. 

Key words: digital electro-hydraulic control system (DEH), warming up logic, speed increasing, reason analysis