Abstract: Aiming at the characteristics of the vacuum system of 600MW unit, the changes of unit operation parameters caused by local air leakage of the vacuum system were analyzed. The air leakage point was found out; the treatment method was put forward; and relevant measures were adopted. Then the air leakage of the vacuum system did not happen again.
Key words: vacuum system, air leakage, leakage point, hazard, treatment method
FU Kaihui. Analysis on hazard of air leakage in vacuum system of 600MW unit and treatment method[J]. Huadian Technology, 2011, 33(11): 35-36.