Huadian Technology ›› 2011, Vol. 33 ›› Issue (4): 32-34.
• 技术交流 • Previous Articles Next Articles
CAI Youmin1,ZHANG Caiwen2,WAN Zhijiang2, ZHU Ciying1,GUO Yibing1
Received:
Revised:
Published:
Abstract: The vacuum system fault of steam turbine No.2 of L Power Plant in Indonesia was introduced. The reasons caused the vacuum system fault were diagnosed and analyzed. Using the filling water method and the Helium mass spectrum leakage detector to find the leakage point of the vacuum system, the especially big leakage point was found in lower half casing of low pressure cylinder. The effective measures were adopted, and the condenser vacuum leakage fault does not occur again.
Key words: vacuum system fault, Helium mass spectrum leakage detector, leakage detection, treatment measure
CAI Youmin;ZHANG Caiwen;WAN Zhijiang;ZHU Ciying;GUO Yibing. Vacuum system leakage detection method for unit No.2 of L Power Plant in Indonesia[J]. Huadian Technology, 2011, 33(4): 32-34.