Huadian Technology ›› 2011, Vol. 33 ›› Issue (4): 55-56.
• 技术交流 • Previous Articles Next Articles
YAN Chuanwu,WANG Zhangsheng
Received:
Revised:
Published:
Abstract: The structure of mechanical seal of boiler feed pump in a thermal power plant in India and the arrangement of its sealing circulating liquid pipeline were introduced. The working principle of the mechanical seal and the influence of the higher temperature of mechanical sealing liquid on the sealing property were expounded. Combining with practical project, the reasons of the higher temperature of sealing liquid caused by its leakage were analyzed, and relevant solving measures were put forward.
Key words: mechanical seal, liquid film, leakage
YAN Chuanwu;WANG Zhangsheng. Application of mechanical seal in boiler feed pump of power plant and fault analysis[J]. Huadian Technology, 2011, 33(4): 55-56.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2011/V33/I4/55
Comparative analysis of calculation models for thermal efficiencies of waste heat boilers in gassteam combined cycle units