Huadian Technology ›› 2011, Vol. 33 ›› Issue (5): 37-39.
• 技术交流 • Previous Articles Next Articles
WEI Leihua
Received:
Revised:
Online:
Published:
Abstract: An emergency shutdown of the generator set in a hydropower station caused by the higher temperature of the radial bearing was introduced. The reasons of the shutdown accident were analyzed. The accident lessons were summarized. The preventive measures were put forward, and similar accident can be prevented.
Key words: generator set of a hydropower station, radial bearing, higher temperature, emergency shutdown, analysis and treatment
WEI Leihua. Analysis and treatment of emergency shutdown caused by higher temperature of radial bearing[J]. Huadian Technology, 2011, 33(5): 37-39.