Analysis and treatment of emergency shutdown caused by higher temperature of radial bearing

WEI Leihua   

  1. Administration Office of Feilaixia Water Conservancy Project, Qingyuan 511825, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-05-25 Published:2011-05-25

Abstract: An emergency shutdown of the generator set in a hydropower station caused by the higher temperature of the radial bearing was introduced. The reasons of the shutdown accident were analyzed. The accident lessons were summarized. The preventive measures were put forward, and similar accident can be prevented.

Key words: generator set of a hydropower station, radial bearing, higher temperature, emergency shutdown, analysis and treatment