Abstract: Since the two 200MW units of Zhengdong New District Thermal Power Plant were put into operation, some problems exist in turbine lube oil system, for example, the oil seems not too transparent, and the water content in the oil is out of limit. By using of the airsealing oil baffle, the bearing boxes of HP cylinder and IP cylinder of the turbine were reformed. After the reformation, the problem of higher water content in the lube oil was solved; the operation and maintenance cost was decreased greatly; the effect of the reformation is extremely significant.
Key words: lube oil, labyrinth oil baffle, air-sealing oil baffle, reformation
WANG Haibo;XU Xu. Reformation of oil baffle of domestic 200MW steam turbine[J]. Huadian Technology, 2011, 33(7): 12-13.