Abstract: The composition of the startup system of the Wflame supercritical boiler in coalelectricity integrated Corporation Limited of Guodian Xingyang Power Plant was introduced. The automatic control features of the startup system were analyzed. Combining with the startup system operation mode and the control strategy, the procedures of boiler water circulating, boiler ignition, boiler pressure raising and turning into oncethrough operation mode were determined.
Key words: W-flame boiler, start-up system, valve, automatic control
LI Youxin;WANG Lei;LIU Jingyu. Startup system of supercritical Wflame boiler and its automatic control features[J]. Huadian Technology, 2011, 33(7): 21-23.