Huadian Technology ›› 2011, Vol. 33 ›› Issue (7): 37-40.
• 技术交流 • Previous Articles Next Articles
SUN Haiyuan, LI Dewen, FAN Xiaoming
Received:
Revised:
Published:
Abstract: After the boiler No.3 of Huadian Weifang Power Generation Corporation Limited was put into operation in 2006, the heat deviation existed between the left and right tube walls of the heating surface, which easily causes the overtemperature in tube walls; and tube cracking accident had happened repeatedly. The reasons of boiler combustion heat deviation and steam temperature deviation were found; the reasonable reformation scheme and operation and adjustment measures were drawn up. The feasibility of reformation scheme and the measures was demonstrated by the test data. The scheme and measures were put into practical use successfully.
Key words: lean coal-fired boiler, high temperature heating surface, heat deviation, overtemperature, reformatio
SUN Haiyuan;LI Dewen;FAN Xiaoming. Analysis on reasons of larger heat deviation of high temperature heating surface of 670MW lean coalfired boiler and improvement[J]. Huadian Technology, 2011, 33(7): 37-40.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2011/V33/I7/37