Huadian Technology ›› 2011, Vol. 33 ›› Issue (7): 56-58.
• 技术交流 • Previous Articles Next Articles
LIU Ping, L Pengfei
Received:
Revised:
Published:
Abstract: The structure and the functions of HP main steam valve and HP governing valve of 600MW supercritical unit in a power plant were introduced. The reasons of jam fault of HP main steam valve and HP governing valve were analyzed; and concrete methods and measures to prevent the jam fault of HP main steam valve and HP governing valve were put forward.
Key words: high pressure (HP) main steam valve, backing-stop screw, high pressure(HP) governing valve, jam, high-temperature oxide skin, preventive measure
LIU Ping;L Pengfei. Analysis on reasons of jam fault of HP main steam valve and HP governing valve and preventive measures[J]. Huadian Technology, 2011, 33(7): 56-58.