Huadian Technology ›› 2012, Vol. 34 ›› Issue (1): 51-53.
• 技术交流 • Previous Articles Next Articles
YAO Zhongdong
Received:
Revised:
Online:
Published:
Abstract: The reason of flameout of the 300MW tower type boiler in Yaomeng Power Generation Company Limited was analyzed. Based on the coldstate kinetic field experiment and targeted combustion adjustment experiment, the origin of the problem was found. According to the actual situation of the power plant, a rational operation adjustment scheme and preventive measures were put forward. The practical result shows that the boiler combustion condition was improved obviously, and the flameout fault does not occur again.
Key words: tower type boiler, flameout, cold-state kinetic field, stability of combustion
YAO Zhongdong. Analysis and adjustment strategy of the flameout of 300MW tower type boiler[J]. Huadian Technology, 2012, 34(1): 51-53.