Huadian Technology ›› 2012, Vol. 34 ›› Issue (1): 51-53.

• 技术交流 • Previous Articles     Next Articles

Analysis and adjustment strategy of the flameout of 300MW tower type boiler

YAO Zhongdong   

  1. Yaomeng Power Generation Company Limited, Pingdingshan 467031, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-01-25 Published:2012-01-25

Abstract: The reason of flameout of the 300MW tower type boiler in Yaomeng Power Generation Company Limited was analyzed. Based on the coldstate kinetic field experiment and targeted combustion adjustment experiment, the origin of the problem was found. According to the actual situation of the power plant, a rational operation adjustment scheme and preventive measures were put forward. The practical result shows that the boiler combustion condition was improved obviously, and the flameout fault does not occur again.

Key words: tower type boiler, flameout, cold-state kinetic field, stability of combustion