Huadian Technology ›› 2012, Vol. 34 ›› Issue (1): 54-56.

• 技术交流 • Previous Articles     Next Articles

Analysis on wrong shutdown accident caused by oil level measurement of main oil tank

WANG Linhui   

  1. Shandong Nuclear Power Company Limited, Yantai 265116, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-01-25 Published:2012-01-25

Abstract: The lubrication oil system of the unit was introduced. Based on this, a wrong shutdown accident caused by oil level measurement of main oil tank was analyzed. The fault had been inspected. A treatment scheme was put forward; and the accident does not occur again.

Key words: lubrication oil, main oil tank, oil ejector, oil level measurement, returned oil screen, fault analysis, treatment scheme