Huadian Technology ›› 2012, Vol. 34 ›› Issue (1): 73-75.

• 新能源 • Previous Articles    

Analysis on reasons of unbalance of threephase currents of double feed asynchronous wind power generator stator

DI Hailong, LIANG Zhenfei, WANG Bo   

  1. Inner Mongolia Huadian Huitengxile Wind Power Generation Company Limited, Hohhot 010020, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-01-25 Published:2012-01-25

Abstract: In the double feed asynchronous wind power generators No.62 and No.41 of the Inner Mongolia Huadian Huitengxile Wind Power Generation Company Limited, the unbalance faults of stators threephase currents had occurred one after another. The reasons of the faults were analyzed and tested; the concrete fault positions were found out. The result of this paper can be used as reference for other wind power farms in stator overhaul of double feed asynchronous wind power generators.

Key words: double feed asynchronous, wind power generator, stator, three-phase currents, unbalance