Huadian Technology ›› 2012, Vol. 34 ›› Issue (1): 73-75.
• 新能源 • Previous Articles
DI Hailong, LIANG Zhenfei, WANG Bo
Received:
Revised:
Online:
Published:
Abstract: In the double feed asynchronous wind power generators No.62 and No.41 of the Inner Mongolia Huadian Huitengxile Wind Power Generation Company Limited, the unbalance faults of stators threephase currents had occurred one after another. The reasons of the faults were analyzed and tested; the concrete fault positions were found out. The result of this paper can be used as reference for other wind power farms in stator overhaul of double feed asynchronous wind power generators.
Key words: double feed asynchronous, wind power generator, stator, three-phase currents, unbalance
DI Hailong;LIANG Zhenfei;WANG Bo. Analysis on reasons of unbalance of threephase currents of double feed asynchronous wind power generator stator[J]. Huadian Technology, 2012, 34(1): 73-75.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2012/V34/I1/73
Field test, analysis and recommendations for injection stator grounding protection