Huadian Technology ›› 2012, Vol. 34 ›› Issue (2): 68-71.

• 节能与环保 • Previous Articles     Next Articles

A new slurry density measurement device for desulphurization system

WANG Yang1, REN Zhen2, SHEN Yuhui1, DENG Huipeng1   

  1. 1.China Huadian Engineering Corporation Limited, Beijing 100035, China; 2.Huangshi Thermal Power Plant of Huadian Hubei Power Generation Company Limited, Huangshi 435002, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-02-25 Published:2012-02-25

Abstract:

The current slurry density measurement methods used in desulphurization systems were introduced. Aiming at the defects of the existing measurement devices, a comprehensive measurement device using differential pressure method was developed; the slurry density measurement function of the developed device is accurate, stable and reliable, and the device has pH value measurement and field sampling functions too. The device, in which the density measurement, the pH value measurement and the sampling were integrated, has advantages of lower cost, good operation stability, high measurement accuracy and long service life, so it can make favorable economical benefit and social effect. 

Key words: desulphurization, slurry, density measurement, differential pressure method for density measurement