Abstract: The hightemperature corrosion occurred in the water walls of two 660MW supercritical oncethrough boilers in a power generation company limited. The factors leading to hightemperature corrosion of the water wall were pointed out. The gas temperature and the chemical components of the gas in side wall of water wall were detected. The reasons of the hightemperature corrosion of water wall were analyzed; and the relevant preventive measures were proposed.
Key words: water wall, high-temperature corrosion, reason analysis, preventive measure
CHEN Kelu;RAO Hongjian. Analysis on reasons of hightemperature corrosion of water wall in 660MW unit boiler and countermeasures[J]. Huadian Technology, 2012, 34(5): 8-9.