[1] |
FENG Guangjie,WANG Zhiyong,YAN Zhihui,HU Shasha,WANG Zhiwei,XIAO Feng.
An improvement scheme for busbar differential protection logic applied in singlesectionalized doublebusbar connection mode
[J]. Huadian Technology, 2020, 42(1): 45-49.
|
[2] |
ZHANG Yonggang1, 2,WANG Yue3,YAO Liang1, 2,CHEN Qi1, 2.
Research on a differential current protection device for Tconnection lines
[J]. Huadian Technology, 2019, 41(2): 18-21.
|
[3] |
ZHOU Linlin,WANG Kebin,YU Yi.
Cause analysis on opencircuit of CT secondary circuit for measuring at generator end
[J]. Huadian Technology, 2019, 41(1): 67-68.
|
[4] |
DU Xilai.
Ground point principle and case analysis of current transformer
[J]. Huadian Technology, 2018, 40(8): 31-33.
|
[5] |
QI Jie.
Fault analysis of a 600MW hydrogenerator stator winding damage
[J]. Huadian Technology, 2018, 40(12): 16-19.
|
[6] |
XUE Mingjun1,2, WANG Yuting1,2, CHEN Fufeng1,2, ZOU Lei1,2, ZHANG Xiang1,2, CHEN Shi1,2.
Influence of series compensated double circuits on the same tower zerosequence component to relay protection
[J]. Huadian Technology, 2017, 39(9): 6-9.
|
[7] |
KANG Feng,WANG Runyi,ZHANG Wei,LIU Qinghai,YANG Qingsong.
The design and implementation of differential protection based on current differential harmonic content
[J]. Huadian Technology, 2017, 39(7): 32-35.
|
[8] |
TANG Zhiguo,ZHOU Xiaobo,CHEN Qi,WANG Yongxu,CHEN Hongyan.
Busbar abnormal great number detection method based on virtual difference current technology
[J]. Huadian Technology, 2017, 39(4): 1-3.
|
[9] |
ZHANG Yanlin, WANG Peng, HAN Yingjie, FAN Yusheng, LIU Zheng.
A study of differential protection of variablefrequency motor and its applications
[J]. Huadian Technology, 2017, 39(4): 8-10.
|
[10] |
HU Bing, GUO Xiao, CHEN Shi, XING Wu, WANG Zhe.
Differential protection research of voltage regulating transformer of rectifier unit and its application
[J]. Huadian Technology, 2017, 39(1): 14-17.
|
[11] |
XU Liqing, SHI Zhiwei, YU Huawu, DONG Jincai.
The anti interference design of analog integrator for electronic current transformer
[J]. Huadian Technology, 2016, 38(5): 1-3.
|
[12] |
HE Liping1,LI Chunliang1,HUANG Zuwei1,CAI Zhaoyu1,ZHOU Zhiqin2,YIN Hao2.
Abstract:To guarantee the stability and operation safety of power grid,on load test of new equipment shall be carried out before put into operation.After test on capacitor,electric reactor,cable and transformer,angle of attack charter of voltage,current and load flow value was drafted.After analyzing test results,the causes of change of current,voltage and phase was indicated.
[J]. Huadian Technology, 2016, 38(2): 55-58.
|
[13] |
WANG Song1, WU Pengyue2, SUN Ganghu2, WANG Zhigao1, GAN Jianghua3.
Analysis on fault of loose connection of terminals in secondary circuit of current transformer
[J]. Huadian Technology, 2015, 37(4): 19-21.
|
[14] |
LIAO Hongtao.
Analysis on false action of main transformer differential protection responding outside area fault caused by twopoint grounding of secondary current circuit
[J]. Huadian Technology, 2015, 37(1): 55-57.
|
[15] |
WEN Tao.
Test program of differential protection for generator and transformer of AP1000 nuclear power unit
[J]. Huadian Technology, 2014, 36(4): 73-76.
|