Huadian Technology ›› 2013, Vol. 35 ›› Issue (3): 8-8.
• 专题综述 • Previous Articles Next Articles
LIN Fuhai
Received:
Revised:
Published:
Abstract: Taking the condensate polishing system without condensate makeup water tank of a power plant as example, the operational aspects of the condensate polishing system in processes of startup and normal operation of the unit were analyzed. Some concrete treatment measures were given, which can be used as reference for other units operating in similar mode.
Key words: thermal power plant, steam condenser, condensate make-up water tank, condensate polishing, operation mode
LIN Fuhai. Analysis on operation of condensate polishing system without condensate makeup water tank[J]. Huadian Technology, 2013, 35(3): 8-8.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2013/V35/I3/8
Fault analysis on desulfurization DCS signal interference in a thermal power plant
Quality evaluation and performance analysis of WC9 cast steel safety valve for inservice units in a thermal power plant
Experimental study on electrochemical technology for circulating water treatment in thermal power plant