Huadian Technology ›› 2013, Vol. 35 ›› Issue (4): 52-54.

• 节能与环保 • Previous Articles     Next Articles

Analysis on pollution of continuous electrodialysis deionization device and regeneration process

JIANG Xiaohu1, FU Shihai1, SU Xuefeng2   

  1. (1.Guodian Nanjing Automation Company Limited, Nanjing 210032, China;2.Xinjiang Joinworld Company Limited, Urumqi 830013, China)
  • Received:1900-01-01 Revised:1900-01-01 Published:2013-04-25

Abstract: he characteristics of continuous electrodialysis deionization technology were introduced. The relation between the continuous electrodialysis deionization technology and the full membrane treatment process was expounded. Based on this, the problems occurred in operation of the continuous electrodialysis deionization device were analyzed, and solving methods were put forward.

Key words: continuous electrodialysis deionization (EDI) device, ultrafiltration, reverse osmosis, full membrane treatment process, pollution analysis, solving method