Huadian Technology ›› 2013, Vol. 35 ›› Issue (5): 7-9.
• 专题综述 • Previous Articles Next Articles
ZHANG Quan
Received:
Revised:
Online:
Published:
Abstract: Taking the reformation of terminal steam seal of the domestic 300MW unit turbine in a power plant as example, the deficiencies of the traditional steam seal were analyzed. The features of the lateral tooth steam seal were introduced. After the terminal steam seal of the steam turbine in the power plant was transformed into lateral tooth steam seal, the steam leakage of the terminal shaft seal of the turbine decreased by 0.45~0.85t/h,the microwater content in lubrication oil decreased significantly, the efficiency of HP and IP cylinder was improved, and the steam consumption of the unit was reduced.
Key words: steam turbine, shaft seal, lateral tooth steam seal, steam leakage
ZHANG Quan. Analysis on application of lateral tooth steam seal in domestic 300MW steam turbine[J]. Huadian Technology, 2013, 35(5): 7-9.