Abstract: Abstract:Taking the final assembly clearance control of the steam seal of the turbine in AP1000 nuclear power unit as example, the characteristics of the laser clearance measurement method and the characteristics of the conventional clearance measurement method were analyzed, and the advantages and disadvantages of the two methods were compared. The laser clearance measurement method was adopted for measuring, and the conventional clearance measurement method was adopted for verifying. So the rationality of the final assembly clearance of steam seal was ensured.
Key words: Key words:steam turbine, clearance measurement, turbine clearance measurement control system, press lead wire testing method, comparison and analysis
ZHANG Zhenyu, SHU Zhengyu. Comparison of steam turbine clearance measurement control system and conventional clearance measurement method[J]. Huadian Technology, 2013, 35(9): 27-31.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2013/V35/I9/27
Analysis on application of new steam seal clearance measurement technology for steam turbine