Huadian Technology ›› 2014, Vol. 36 ›› Issue (1): 52-53.
Previous Articles Next Articles
Published:
Abstract: Abstract:In the 670MW unit of a power generation company, the deaerator vibration phenomenon occurred several times during startingup initial stage of the deaerator. The vibration damaged the deaerator base and caused some cracks in the base, which not only influences on the equipment safety seriously, but also influences the startup speed of the whole unit. Aiming at this phenomenon, the site situation was investigated; the reason of the vibration was analyzed; the solution was proposed; and the vibration had been eliminated ultimately.
Key words: Keywords:steam turbine, deaerator, vibration, heating steam source, temperature raising speed
WANG Bin, WANG Lanlin, WU Tao, LIU Zunping. Analysis on vibration of deaerator in startingup initial stage and eliminating method[J]. Huadian Technology, 2014, 36(1): 52-53.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2014/V36/I1/52
Study on the structure design of quadrangle towerframe steel chimney
Influence of 600MW supercritical unit steam distribution characteristics on shaft vibration
Analysis and treatment of abnormal vibration of industrial water pump
Analysis and treatment of abnormal vibration of a steam turbine of 600MW unit