Huadian Technology ›› 2014, Vol. 36 ›› Issue (10): 38-39.
Previous Articles Next Articles
Published:
Abstract: Abstract:The acid value of the fireresistant oil of the unit No.1 in a power plant increased abnormally. The reason of acid value increase was analyzed. The concrete measures to prevent fireresistant oil hydrolysis, which can cause acid value to increase, were proposed.
Key words: Keywords:fireresistant oil, acid value, hydrolysis
HE Wenbo. Analysis and treatment of too high acid value of fireresistant oil[J]. Huadian Technology, 2014, 36(10): 38-39.