Analysis on reasons of leakage area formation of boiler heating surface in 300MW unit and maintenance and prevention

  

  1. (1.Huadian International Zouxian Power Plant, Zoucheng 273522, China; 2.Yantai Ebara Air Conditioner Corporation Limited, Yantai 265500, China)
  • Published:2014-10-25

Abstract: Abstract:The corrosion and damage of boiler heating surface of two 300MW units in Huadian International Zouxian Power Plant were analyzed. The treatment countermeasures were proposed. The maintenance and prevention methods were summarized. The results in this paper provide countermeasures to handling with the other boiler heating surface leakage fault.

Key words: Keywords:300MW, boiler heating surface, leakage treatment, maintenance and prevention