Huadian Technology ›› 2014, Vol. 36 ›› Issue (3): 57-59.
Previous Articles Next Articles
Published:
Abstract: Abstract:After the 1000MW unit of Guangdong Datang International Chaozhou Power Generation Company Limited operated for three years, the strainer of servo valve was blocked, which caused the valve opened slowly, and the deviation between instruct and feedback signal increased.The working principle of the servo valve was introduced, and the requirements of normal operation and maintenance of the servo valve and the speed governing system were proposed.The fault and reasons were analyzed,the correctness of the analysis was verified by treatment and disassembly.
Key words: Keywords:valve, servo valve, strainer, blockage, slow
WANG Hui. Analysis on reasons of slow opening process of governor valve and interceptor valve[J]. Huadian Technology, 2014, 36(3): 57-59.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2014/V36/I3/57
Application of acoustic blockage removal technique applied in urea pyrolysis furnaces
Transformation methods for PT slowmelting judgment of UN 5000 excitation system
Analysis on reasons of ash blockage of boiler air preheater and treatment measure