Huadian Technology ›› 2014, Vol. 36 ›› Issue (8): 27-29.

Previous Articles     Next Articles

Case analysis of major shaft fracture for the circulating water pump in a certain power plant

  

  1. (1.Huadian Caofeidian Heavy Equipment Corporation limited, Tangshan 063210,China; 2.Henan Electric Industrial Boiler and Pressure Vessel Inspection Center, Zhengzhou 450052, China)
  • Online:2014-08-25 Published:2014-10-11

Abstract: Abstract:A fracture accident occurred to major shaft of the circulating water pump for the super critical unit in a power plant. The fracture of major shaft for the circulating water pump was inspected, through spectral analysis and metallography were hardness test. According to the test results, the causes of c major shaft fracture of the circulating pump were analyzed, and relative precautionary measures were put forward.

Key words: Keywords:circulating water pump major shaft, fracture, inspection, cause analysis;precautionary measures