Abstract: Abstract:The ammonia spraying automatic control loop of the flue gas deNOx system of 2×600MW unit in Guangdong Yudean Zhuhai Jinwan Power Plant was introduced. There were problems in operation of SCR deNOx system of thermal power plant, such as the selection of the minimum ammonia injection temperature, the too frequent start/stop operation of the ammonia spraying system and the poor effect of the ammonia automatic spraying. The problems were described, and the reasons of the problems were analyzed. The solutions were proposed.
Key words: Keywords:full automatic control of ammonia spraying, minimum operation temperature, flue gas deNOx, selective catalytic reduction (SCR) technology
MAO Yisheng. Optimization of ammonia spraying automatic control loop of flue gas deNOx system[J]. Huadian Technology, 2014, 36(8): 65-67.