Huadian Technology ›› 2015, Vol. 37 ›› Issue (1): 30-33.
Previous Articles Next Articles
Published:
Abstract: Abstract:The YKSL3650-16/2600 type circulating water pump motor of a domestic 1000MW unit was reformed into twospeed motor. After the reformation, the larger vibration occurred in stator part of the motor. According to diagnosis, it was determined that the reason of the vibration is 100Hz resonance. Some methods were used to reduce the unbalance of the magnetic potential, and the vibration problem of the motor was solved.
Key words: Keywords:YKSL3650-16/2600 type circulating water pump, motor, twospeed reformation, resonance
CAO Jingfang. Analysis on reasons of vibration of circulating water pump twospeed motor of 1000MW unit and treatment[J]. Huadian Technology, 2015, 37(1): 30-33.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2015/V37/I1/30
Exploration of permanent magnet speed regulation energysaving technology and its application on 6kV motors