Huadian Technology ›› 2015, Vol. 37 ›› Issue (1): 30-33.

Previous Articles     Next Articles

Analysis on reasons of vibration of circulating water pump twospeed motor of 1000MW unit and treatment

  

  1. (Huadian International Zouxian Power Plant, Zoucheng 273522, China)
  • Online:2015-01-25 Published:2015-03-25

Abstract: Abstract:The YKSL3650-16/2600 type circulating water pump motor of a domestic 1000MW unit was reformed into twospeed motor. After the reformation, the larger vibration occurred in stator part of the motor. According to diagnosis, it was determined that the reason of the vibration is 100Hz resonance. Some methods were used to reduce the unbalance of the magnetic potential, and the vibration problem of the motor was solved.

Key words: Keywords:YKSL3650-16/2600 type circulating water pump, motor, twospeed reformation, resonance