Huadian Technology ›› 2015, Vol. 37 ›› Issue (4): 52-54.
Previous Articles Next Articles
Published:
Abstract: Abstract:Taking the unit No.7 of Zhouxian Power Plant as example, the situation of feedwater treatment by all volatile treatment technology and oxygenation treatment technology was traced. Based on comparison of the water steam quality, the deposition on the water wall and the pressure losses of feedwater system, it was shown that the oxygenation treatment is more safe and economical operation mode for ultra supercritical oncethrough boiler unit.
Key words: Keywords:1000MW unit, ultra supercritical unit, all volatile treatment, oxygenation treatment, feedwater
CUI Shaobo, SUN Wei, MA Wei. Analysis on application of feedwater oxygenation treatment for unit No.7 of Zouxian Power Plant[J]. Huadian Technology, 2015, 37(4): 52-54.