Huadian Technology ›› 2015, Vol. 37 ›› Issue (7): 27-28.
Previous Articles Next Articles
Published:
Abstract:
Abstract:The air preheater LAP17286/2250, manufactured by Dongfang Boiler Works Group Corporation Limited, was selected for the 1000MW unit of China Huadian Corporation. The lower bearing damage fault of the air preheater occurred three times for recent years. The fault was analyzed. Some improvement suggestions were proposed, which include to enhance the manaement of spare cceptance check, to normalize the technical management and others. The unit safe and stable operation was ensured.
Key words: Keywords:air preheater, lower bearing, damage, acceptance check
SHAO Changnuan, SUN Weiju. Analysis on reason of damage of air preheater lower bearing of 1000MW ultra supercritical unit[J]. Huadian Technology, 2015, 37(7): 27-28.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/