Huadian Technology ›› 2015, Vol. 37 ›› Issue (9): 22-24.
Previous Articles Next Articles
Published:
Abstract:
Abstract:According to the survey results of rotary air preheaters in large capacity thermal power units,the performances of more than 80% of rotary air preheaters appear different degree of deterioration and that caused the decreasing of unit output.This paper built the performance diagnosis model and found the reason that caused the performance decreasing of a rotary air preheater,and then it proposed preventive measures to ensure the safe running of an air preheater,which were proved effective by living examples.
Key words: Keywords:air preheater, diagnosis model, leakage rate, dynamic debugging
WANG Chengliang. The performance diagnosis model of a rotary air preheater and its application analysis[J]. Huadian Technology, 2015, 37(9): 22-24.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2015/V37/I9/22
Optimization of air preheater leakage control system in 670MW unit