Huadian Technology ›› 2016, Vol. 38 ›› Issue (1): 59-61.
Previous Articles Next Articles
Published:
Abstract:
Abstract:The NOx emission concentration of an air preheater is up to 655.7mg/m3 for the No.6 unit of a certain power plant.In order to meet the emission requirement of new standard,a low NOx combustion retrofit of boiler burners conducted using a multi air stereo staged and horizontal bias coal combustion technology,which carries out a multi air stereo staged combustion along the vertical direction and horizontal direction in the chamber of a stove.The performance test of the retrofitted boiler shows that the retrofit effect is significant with the NOx emission concentration of an air preheater could be kept below 300mg/m3 for a long time,and the boiler efficiency and combustible matter content in flue dust are also meeting the requirements.
Key words: Keywords:burner, low NOx combustion, NOx, air stereo staged combustion, horizontal bias
FAN Aibing. Low NOx combustion retrofit of boilerand its effect analysis for 330MW power unit[J]. Huadian Technology, 2016, 38(1): 59-61.