Thermal power plant high pressure water supply pipe vibration diagnostic and treatment

  

  1. China Huadian Electrical Power Technology Research Institute, Hangzhou 310030, China
  • Online:2016-10-25 Published:2016-11-23

Abstract:

Abstract:Based on the incident of a power plant’s high pressure water supply pipe vibration, by study vibration formula, combined with macroscopic observe, vibration test, simulation analysis and other methods, utilizing rigid limit, hydraulic damper and viscous fluid damper, a pipe vibration control method was established. Which could be referred for thermal power plant pipe vibration treatment.

Key words: