Huadian Technology ›› 2016, Vol. 38 ›› Issue (3): 54-57.

Previous Articles     Next Articles

Foul block problem analysis of return valve and its treatments for a certain 670t/h circulating fluidized bed boiler

  

  1. 1.China Power Investment Corporation Jiangxi Branch, Nanchang 330006,China; 2.Jiangxi Zhongdian Power Engineering Company Limited Jingdezhen Branch,Jingdezhen 333000, China
  • Online:2016-03-25 Published:2016-05-18

Abstract:

Abstract:The foul block problem of return valve standpipe of a certain circulating fluidized bed boiler is frequently occurred. Through analyzing,
this paper found that the main reason is the low pressure of high-pressure fluid air,and proposed some pertinence measures from the aspects of operation,equipment transformation and technical management.After that,foul block problem of return valve standpipe is solved satisfactorily.

Key words:  ,