Huadian Technology ›› 2016, Vol. 38 ›› Issue (8): 59-60.

Previous Articles     Next Articles

330MW boiler water wall breakage analysis and preventive measures

  

  1. Huadian International Shiliquan Power Plant, Zaozhuang 277103, China
  • Online:2016-08-25 Published:2016-10-31

Abstract:

Abstract:Water wall is the main evaporating heating surface of boiler. Once boiler stopped by water wall breakage, power generating and heat supply will be directly affected. Thus to have knowledge of water wall breakage causes and preventive measures is essential. Water wall breakage was analyzed. Preventive measures were provided.