600MW ultracritical thermal power unit primary frequency modulation disqualification analysis and logic improvement

  

  1. Fujian Huadian Kemen Power Generation Company Limited, Fuzhou 350001, China
  • Online:2017-01-25 Published:2017-03-23

Abstract:

Abstract:Took the incident of primary frequency modulation disqualification happened in Fujian Huadian Kemen Power Generation Company Limited unit 4, the principle of 600MW ultracritical thermal power unit primary frequency modulation was introduced. Combine with the practice, the plan for logic improvement was indicated. 

Key words: