Huadian Technology ›› 2017, Vol. 39 ›› Issue (1): 50-52.

Previous Articles     Next Articles

300MW bleeder turbine collision and friction cause analysis

  

  1. Datang CentralChina Electric Power Test Research Institute, Zhengzhou 450000,China
  • Online:2017-01-25 Published:2017-03-23

Abstract:

Abstract:Collision and friction happened in the highlow pressure flow passage area along shaft while the first startup of 300MW bleeder turbine after retrofit. After analyzing collision and friction causes, based on the calculation of highlow pressure flow passage area running clearance of each two stages, the first collided and fricated part was indicated. Improvement suggestion was provided. 

Key words: