Huadian Technology ›› 2017, Vol. 39 ›› Issue (10): 56-57.

Previous Articles     Next Articles

 
1000MW unit highspeed mixed bed resin leakage accident analysis

  

  1. Huadian Laizhou Generation Company Limited, Yantai 261400, China
  • Online:2017-10-25 Published:2017-11-22

Abstract:

 

The problem of a thermal power plant’s 1000MW unit prefilter abnormal pressure differential, highspeed mixed bed resin leakage and resin catcher leakage comprehensive analyzed. The main causes were indicated as large quantity of water soluble paper was imported into system by mistake, ignoration of reheater cleanup procedure and resin catcher seal washer aging. Treatment measures were indicated accordingly.

CLC Number: