Abstract:

Based on the requirement of Transformation and Upgrading of Coal for Energy Conservation and Emissions Reduction Plan of Action 2014 to 2020, the energyconsumption index of Zhanjiang Zhongyue Energy Company Limited’s 600MW unite was too high. After studying on steam turbine path flow, boiler heating surface, outside steam cooler, vacuum system, thermodynamic system, air preheater, circulating pump and theoretical calculation, net coal consumption would be lowered to 19g/(kW·h).This paper could be referred by similar unit and project.