Huadian Technology ›› 2017, Vol. 39 ›› Issue (6): 23-24.

Previous Articles     Next Articles

Separator transformation and optimization of doubleinlet and doubleoutlet coal mill for a 300MW unit

  

  1. 1.Shijiazhuang Liangcun Thermal Power Company Limited, Shijiazhuang 052165, China; 2.School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China; 3.Xi’an Green Power Technology Company Limited, Xi’an 710043, China
  • Online:2017-06-25 Published:2017-07-10

Abstract:

:For the 300MW boiler in Shijiazhuang Liangcun Thermal Power Company Limited, a MGS4062 type doubleinlet and doubleoutlet coal mill is adopted. As the declining of coal quality and the increasing of coal impurities, there is a serious blocking problem for the matched radial baffle type separator, which influences the unit load capacity. Through transforming the separator into a twostage axial type and adding impurity filters at powder outlet and inclined powder returning pipe, the pulverized coal uniformity index is greater than or equal to 1, coal mill unit consumption decreases by 12.2% and coal mill capacity increases by 36% under normal capacity condition. Meanwhile, the impurities of coal are filtered and cleaned out to avoid blocking the primary air pipe and clapper.